Approx. 9 min read
An earthing system is one of the key elements of electrical safety, helping protect people against the risk of electric shock. This article provides detailed information on how earthing works, its types, earth resistance, the materials used and the safety requirements applicable in Azerbaijan.
Torpaqlama nədir?

Electrical system safety depends on more than good-quality cables and protective equipment. A properly designed earthing system is also essential for protecting people and equipment in electrical installations.

So, what is earthing, how does it work and why is it needed? This article explains the main functions and types of electrical earthing, the materials used and the technical requirements applicable in Azerbaijan.

What is earthing?

Earthing, also called grounding, is the intentional electrical connection of specified points or conductive parts of an electrical installation to an earthing arrangement.

One of the main purposes of earthing in electrical safety is to reduce the risk of exposure to dangerous touch voltages when insulation fails.

For example, if insulation inside an electric motor is damaged, its metal enclosure, which is normally not live, may become hazardous.

Properly installed protective earthing and a coordinated automatic disconnection system help prevent the dangerous consequences of such faults.

Important: Earthing is not simply a matter of sending electric current into the soil. The fault current path depends on the supply's earthing arrangement. Protective conductors, equipotential bonding and automatic disconnection devices must work together correctly to provide safety.

Why is earthing needed?

Electrical earthing is an important part of the electrical safety system in residential and public buildings, as well as industrial and manufacturing facilities.

1. Protecting people against electric shock

If a fault causes a dangerous voltage to appear on the metal enclosure of electrical equipment, touching that enclosure can have serious consequences.

Protective earthing works with other safety measures to reduce this risk.

2. Helping protective devices operate correctly

Correct earthing and protective conductor arrangements are important for circuit-breakers or residual current devices to operate as required under certain fault conditions.

However, the presence of an earth electrode alone does not demonstrate that automatic disconnection is assured. This also depends on the supply arrangement and the characteristics of the protective devices.

3. Reducing dangerous potential differences

Dangerous voltage differences can arise between simultaneously accessible metal parts in an electrical installation.

Equipotential bonding plays an important role in reducing this risk.

4. Supporting safe operation of electrical installations

Correct earthing forms part of the equipment's protection system. In some applications, it can also support the intended operating conditions and electromagnetic compatibility of equipment.

How does earthing work?

Consider a simple example of the operating principle.

Suppose insulation fails in electrical equipment with a metal enclosure and a line conductor comes into contact with the enclosure.

In a properly designed protection system, the process is as follows:

  1. The equipment's metal enclosure is connected to the relevant earthing system by a protective conductor — the PE conductor.
  2. When a fault occurs, current flows in the protective circuit according to the supply arrangement.
  3. Under the appropriate conditions, a circuit-breaker or residual current device detects the fault and disconnects the supply.
  4. The duration of exposure to a dangerous touch voltage is limited.

For this principle to work, the reliability of electrical connections, circuit characteristics and selection of protective devices must be assessed together.

Remember: Earthing does not replace a circuit-breaker or residual current device. Equally, a residual current device does not replace required protective earthing.

Main types of earthing

Earthing should be distinguished by its purpose and by the arrangement of the electrical supply system.

Protective earthing

Protective earthing is used to reduce the risk of injury from electric shock.

Examples include the protection of metal parts of motors, distribution boards and other equipment that are normally not live but could become live if insulation fails.

Operational or functional earthing

This type of earthing is used to provide the intended operating conditions of certain electrical systems.

Depending on the application, it may include earthing the neutral point of a supply system or meeting the functional requirements of specialised equipment.

Earthing arrangements in supply systems

The following arrangements are used in electrical supply systems:

  • TN system: The equipment's exposed-conductive-parts are connected by protective conductors to the earthed neutral of the supply. TN-S and TN-C-S are commonly used variants.
  • TT system: The equipment's exposed-conductive-parts are earthed through an earthing arrangement electrically independent of the supply's earthed neutral.
  • IT system: The supply is isolated from earth or connected to earth through a high impedance. Insulation monitoring is particularly important in this system.

The arrangement to be used is determined by the electrical supply design and applicable requirements.

Main components of an earthing system

An earthing system may include several conductive and connecting components.

Earth electrodes

These are metal elements that establish electrical contact with the soil. Depending on the design, vertical electrodes, horizontal conductors and other suitable arrangements may be used.

Electrode material, dimensions and placement are selected according to soil conditions, corrosion risk and design calculations.

Earthing strips and conductors

Earthing strips, including galvanised steel strips, can be used to make conductive connections in earthing and equipotential bonding systems.

The TIM Electro catalogue lists galvanised earthing strips in 30×3 mm and 40×4 mm sizes.

These dimensions indicate strip width and thickness. However, dimensions alone do not establish suitability for every project. Material, required conductor cross-section, fault current and the corrosive environment must be considered.

Explore suitable products in the earthing strips and conductors collection.

Earthing clamps and connectors

Earthing clamps, strip connectors and fixings provide reliable electrical and mechanical connections between parts of the system.

When selecting a connector, check conductor dimensions, material compatibility, installation conditions and the manufacturer's technical specifications.

Explore the relevant product groups in TIM Electro's earthing connectors and fixings collection.

Protective conductors and the main earthing terminal

PE conductors connect the equipment's protected metal parts to the relevant system.

In accordance with the design, the main earthing terminal connects protective conductors, earthing conductors and equipotential bonding conductors.

What earthing methods are used?

Different construction arrangements are available depending on how the earth electrodes are installed.

Vertical earthing: Uses suitable metal electrodes installed vertically in the soil.

Horizontal earthing: Uses strips or other conductive elements installed in the soil.

Combined earthing: Uses vertical and horizontal electrodes together.

Natural earth electrodes: Where permitted by applicable requirements, certain structural elements and other suitable conductive parts may be incorporated into the earthing arrangement.

The method depends on the installation's purpose, soil resistivity, project requirements and protection system calculations.

What is earth resistance?

Earth resistance is a technical characteristic associated with the resistance an earthing arrangement presents to the flow of current into the soil. It is expressed in ohms (Ω).

Soil properties, moisture, temperature, electrode dimensions and placement, and other factors can affect this value.

What should the earth resistance be?

There is no single resistance value that applies to all electrical installations.

Requirements depend on the type of installation, voltage level, TN, TT or IT arrangement, protective devices and applicable regulations.

For example, a resistance limit specified for one site cannot automatically be applied to another installation.

Earth resistance and protective circuit compliance must be checked by qualified professionals using dedicated test equipment.

What is the difference between earthing and lightning protection?

Earthing and lightning protection are related, but they are not the same concept.

Protective earthing of electrical installations primarily helps reduce risks from dangerous touch voltages during electrical faults.

A lightning protection system reduces hazards resulting from lightning. It may include air terminals, down conductors, an earth-termination system and other protective components.

The earthing arrangements of the two systems must be coordinated according to the design and applicable requirements.

Explore related products in the lightning protection equipment collection.

Which earthing requirements apply in Azerbaijan?

One of Azerbaijan's main regulatory documents on earthing electrical installations is the Rules for the Installation of Electrical Installations, approved by Decision No. 3-15/3-1-4/2024 of the Ministry of Energy on 27 June 2024. The rules took effect on 1 January 2025.

Section 24 sets out general requirements for earthing electrical installations and protective measures for electrical safety.

These cover protective earthing, automatic disconnection of supply, equipotential bonding and other protective measures.

Separate rules on the technical operation of electrical installations also address inspection of earthing arrangements, testing and documentation of the results.

Earthing design and installation must be based on the requirements applicable to the site and manufacturers' documentation.

Safety note: Unauthorised changes to earthing connections, connecting neutral and protective conductors contrary to the design, or declaring a system safe without testing creates unacceptable risks. Installation and testing must be carried out by appropriately qualified professionals.

Frequently asked questions

What can happen without earthing?

If equipment insulation fails, the protection system may not operate as required. Dangerous voltages may then appear on accessible metal parts.

Are earthing and neutral the same?

No. Neutral (N) and protective (PE) conductors have different functions. Although certain TN systems use a combined PEN conductor, this does not permit arbitrary connections between neutral and protective conductors.

Can earth resistance be measured with an ordinary multimeter?

An ordinary multimeter is not sufficient to assess earth electrode resistance using the required method. Dedicated test equipment and an appropriate measurement procedure are used.

Which material is best for earthing?

There is no universally best material for every installation. Copper, suitably coated steel and other conductive materials are selected according to design requirements, corrosion conditions, mechanical strength and technical compatibility.

When should an earthing system be checked?

The type and frequency of checks depend on the installation's classification and applicable requirements. Necessary electrical measurements must accompany visual inspection.

Conclusion

Earthing plays an important role in the safe operation of electrical installations. A correctly designed system helps reduce the risk of electric shock and enables protective devices to operate as intended.

However, the presence of an earth electrode or strip alone does not ensure safety. Conductors, connectors, equipotential bonding, protective devices and test results must be assessed as a single system.

Looking for earthing products for your project?

Explore earthing strips, conductors, connectors and fixings in the TIM Electro catalogue.

View earthing and lightning protection products.

Contact the TIM Electro team on +994 51 405 99 05 to discuss technical specifications, size compatibility, availability and quotations.